Honeywell Vista-20P Programming Manual
This manual applies to the following controls⁚ VISTA-20P, VISTA-20PS, VISTA-20PCN, VISTA-20PSCN, VISTA-15P, VISTA-15PCN Features and procedures apply to all, except where differences are noted․ References to VISTA-20P apply to both the VISTA-20P and VISTA-20PS, unless noted for VISTA-20PS only․
This manual provides a step-by-step guide to programming your Honeywell VISTA-20P security system․ It covers all aspects of programming, from basic configuration to advanced features․
The Honeywell Vista-20P is a high-capacity, feature-rich smart home security hub that lets you deliver more value to your customers․ With up to 48 zones of protection, graphic keypad support and dual partitions, the VISTA-20P control panel gives your customers the ability to send alarm signals and upload/download via an Internet Protocol (IP), improving the speed at which information can be delivered to and from their VISTA security devices․
This document outlines how to connect your Envisalink4 to a Honeywell Vista Panel (10P/15P/20P/21iP/128/150) and to initially program your Honeywell Vista system․
This PDF programming guide is for the Honeywell ADEMCO VISTA-20P Security Systems․
The Honeywell Vista-15P/Vista-20P Program Guide covers the process for programming a Honeywell VISTA-15P or VISTA-20P․ The guide covers the 56, 57, 58, 78, 79, 80, 81, 82, and 29 fields, among other information․
This manual is a step-by-step guide that will acquaint you with the systems features and benefits․ It defines the components and their functions, describes their operation, and provides clear step-by-step instructions for normal and emergency procedures․
The VISTA-20P control panel is a high-capacity, feature-rich smart home security hub that lets you deliver more value to your customers․
The Honeywell Vista-15P/Vista-20P User Guide provides important information for using a Honeywell VISTA-15P or VISTA-20P․ Each relevant panel feature is covered and explained for the end user․
Introduction
The Honeywell Vista-20P is a powerful and versatile security system that can be customized to meet the specific needs of any home or business․ It offers a wide range of features, including up to 48 zones of protection, graphic keypad support, and dual partitions․ The VISTA-20P control panel allows users to send alarm signals and upload/download information via an Internet Protocol (IP), improving the speed at which information can be delivered to and from their VISTA security devices․
This manual provides a comprehensive guide to programming your VISTA-20P system, covering everything from basic configuration to advanced features․ It is designed to be a valuable resource for both installers and end-users, and it includes detailed instructions, illustrations, and troubleshooting tips․ Whether you are new to the VISTA-20P system or are a seasoned professional, this manual will provide you with the information you need to program and operate your system effectively․
The manual is divided into several sections, each covering a specific aspect of programming․ It also includes a glossary of terms and a troubleshooting guide․ The manual is also available in a digital format, which can be downloaded from the Honeywell website․ This makes it easy to access the manual from any computer or mobile device․
By carefully following the instructions in this manual, you can ensure that your VISTA-20P system is properly programmed and configured to meet your specific security needs․ This will help you to protect your home or business from unauthorized access and ensure peace of mind․
Supported Models
This manual applies to the following Honeywell VISTA series control panels, encompassing a range of features and functionalities to cater to diverse security needs⁚
- VISTA-20P⁚ This model represents the core of the VISTA series, offering a comprehensive set of features for residential and commercial applications․ It provides up to 48 zones of protection, graphic keypad support, and dual partitions․
- VISTA-20PS⁚ A powerful extension of the VISTA-20P, this model includes additional capabilities for enhanced security and system management․ It incorporates features like advanced reporting, remote access, and integration with other smart home devices․
- VISTA-20PCN⁚ Designed for connectivity and communication, this model offers seamless integration with various communication networks․ It supports features like cellular reporting, IP communication, and remote monitoring․
- VISTA-20PSCN⁚ Combining the strengths of the VISTA-20PS and VISTA-20PCN, this model offers a comprehensive solution for advanced security needs․ It includes features like cellular reporting, IP communication, remote monitoring, and enhanced system management․
- VISTA-15P⁚ A compact and versatile model suitable for smaller residential applications, the VISTA-15P offers a balance of features and functionality․ It provides up to 32 zones of protection, keypad support, and basic system management capabilities․
- VISTA-15PCN⁚ Similar to the VISTA-15P, this model incorporates connectivity features for enhanced communication and monitoring․ It supports cellular reporting, IP communication, and remote access․
This manual provides a comprehensive guide to programming all supported VISTA models, highlighting any model-specific differences and procedures․ It ensures that users can effectively program and manage their security systems, regardless of the chosen model․
Programming Modes
The Honeywell VISTA-20P series control panels offer multiple programming modes, each designed to facilitate specific system configurations and adjustments․ Understanding these modes is crucial for effectively programming and managing the security system․
The primary programming mode is accessed through a specific sequence of keystrokes on the control panel’s keypad․ This mode grants access to a wide range of programming options, allowing users to modify system settings, configure zones, define outputs, and manage schedules․
Beyond the primary programming mode, the VISTA-20P series also offers specialized programming menus․ These menus provide focused access to specific aspects of system configuration, streamlining the programming process and ensuring accurate adjustments․ For instance, the “Zone Programming Menu” allows users to program individual zones, defining their type, reporting options, and other parameters․
The programming mode commands are designed to be user-friendly and intuitive․ They are organized into logical groups, making it easy to navigate and identify the desired programming option․ The manual provides detailed instructions and explanations for each programming mode command, guiding users through the process with clarity․
It’s important to note that some programming modes may require specific access levels or codes․ These restrictions are implemented to prevent unauthorized modifications and maintain system security․ The manual provides information on the necessary codes and access levels for each programming mode, ensuring that users can access the appropriate programming options․
Zone Programming
Zone programming is a fundamental aspect of setting up and customizing your Honeywell VISTA-20P security system․ It involves defining the specific characteristics and behaviors of each zone, ensuring they effectively monitor the areas you wish to protect․ This process involves carefully assigning each zone a unique number, determining its type, and configuring its reporting options․
The VISTA-20P system supports a wide range of zone types, catering to different security needs․ These types include “Entry/Exit” zones, which are typically activated by door or window contacts, “Motion” zones triggered by movement, and “Smoke” zones designed to detect fire․ Each zone type is programmed with specific settings that align with its intended function․
Zone programming also involves configuring reporting options․ This dictates how the system communicates alarm events․ You can choose between “Standard” reporting, which sends notifications to your primary phone number, or “Split/Dual” reporting, which sends notifications to both your primary and secondary phone numbers․
The manual provides detailed instructions and worksheets for zone programming․ These resources offer guidance on entering programming mode, navigating the zone programming menus, and making appropriate entries for each zone․ It is crucial to follow these instructions carefully to ensure that each zone is programmed correctly and contributes to the overall security of your system․
By meticulously programming each zone, you can tailor your VISTA-20P system to meet your specific security needs․ This ensures that each protected area is monitored effectively and that the system responds appropriately to any detected threats․
Function Key Programming
Function key programming is a critical part of configuring your Honeywell VISTA-20P security system, allowing you to assign specific actions to the function keys on your keypad․ These keys provide convenient shortcuts for arming, disarming, and performing other system functions․ By customizing these keys, you can streamline your interaction with the system and enhance its user-friendliness․
The VISTA-20P system offers a range of function keys, including “Arm Away,” “Arm Stay,” “Arm Night-Stay,” and “Step Arming․” Each key can be programmed to activate a specific arming mode, depending on your security requirements․ For instance, “Arm Away” might activate a full system arming mode, while “Arm Stay” might allow you to arm certain areas while keeping others unarmed․
The manual provides detailed guidance on programming these function keys․ It outlines the steps involved in entering programming mode, accessing the function key programming menus, and assigning specific actions to each key․ The manual also provides templates and worksheets to help you visualize and organize your function key configurations․
Function key programming allows you to customize your VISTA-20P system for greater convenience and efficiency․ By assigning actions to the function keys that best suit your daily routines, you can interact with the system more intuitively and easily․ This makes it easier to manage your home security and ensure your peace of mind․
Remember that properly programming function keys can significantly enhance the user experience of your VISTA-20P security system․ By tailoring the function keys to your specific needs, you can ensure the system operates seamlessly and effectively meets your security requirements․
Output Definitions
Output definitions play a vital role in the functionality of your Honeywell VISTA-20P security system․ They establish the connections and behaviors of various outputs, such as relays, sirens, and other devices, allowing your system to react to specific events and trigger desired actions․ By properly defining these outputs, you ensure that your system responds appropriately to alarms, zone changes, and other system events․
The VISTA-20P manual provides comprehensive instructions on defining outputs․ It explains the various output types available, including relays, sirens, and other devices․ It also outlines the programming process for configuring each output, specifying its function, activation conditions, and behavior․ This includes setting the output’s response to specific events, such as an alarm activation or a zone change, and determining the duration of the output’s activation․
The manual also provides guidance on associating outputs with specific devices․ For instance, you might configure a relay output to activate a specific door lock or a siren output to sound an alarm during a security breach․ You can also define outputs to activate other system components, such as a notification device or an external communication system․
Output definitions are essential for customizing your VISTA-20P system to meet your specific security needs․ By precisely configuring each output, you ensure that your system responds appropriately to various events and triggers the necessary actions to protect your property and ensure your safety․ Proper output definitions are crucial for a well-functioning and reliable security system․
Schedules
Schedules are a powerful feature of the Honeywell VISTA-20P security system, enabling you to automate various system actions and events based on predefined times and days․ They allow you to schedule arming and disarming of your system, activate specific outputs, and manage other system functions automatically, providing greater convenience and control over your security setup․
The VISTA-20P manual provides detailed instructions on creating and managing schedules․ It explains the different types of schedules available, including those for arming and disarming the system, controlling outputs like lights or sirens, and triggering specific events․ You can set schedules for specific days of the week or for recurring periods, allowing you to tailor them to your specific needs․
The manual also guides you through the process of programming schedules, including defining the time and day of the week for each schedule, selecting the desired action or event, and specifying the associated output or function․ You can program schedules to arm or disarm your system at specific times, activate specific outputs, or trigger other events based on your preferences and daily routines․
Schedules offer a significant advantage for users who desire a hands-free approach to their security system․ By automating actions and events, you can minimize manual intervention and ensure consistent security measures throughout the day and night, even when you are away from home․ Utilizing schedules effectively enhances your security system’s functionality and provides a greater sense of peace of mind․